| Showing 1 - 8 |
| 1) | GOES 6 Energetic Particle Monitor at 3 sec Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/EPM/PT3S | ||||||||||||||||||
| ||||||||||||||||||
| The GOES 6 EPM data set contains various parameters at 3 s resolution. Within the data files is the time given as seconds of the month where the date is given in the filename, a flag word that provides information on the data and satellite command state in a flagword, and the measured counts for a subset of available channels, which are indicated by the flagword. | ||||||||||||||||||
| 2) | GOES 6 Biaxial Fluxgate Magnetometer at 3 sec Resolution in Spacecraft Coordinates |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/MAG/PT3S | ||||||||||||||||||
| ||||||||||||||||||
| The spinning twin-fluxgate magnetometer, located at a few meters away from the spacecraft was designed to provide the orthogonal components of the magnetic field: Hp was parallel to the spin axis that was held nearly in the direction of Earth's axis, He was directed toward Earth center, and Hn pointed eastward. The magnetometer had a range of +/- 400 nT (without saturation) and a resolution of 0.1 nT over a range of +/- 50 nT. The sensitivity of the magnetometer was about 0.2 nT. The instrument and its electronics were carried on board GOES-4,-5,-6,and -7, without significant changes. Data during the first 3 months of 1986 has poor quality Hp component. The experiment became inoperational in February, 1987. | ||||||||||||||||||
| 3) | GOES 6 Space Evironment Monitor Data at 5 min Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/SEM/A/PT5M | ||||||||||||||||||
| ||||||||||||||||||
| This GOES 6 SEM data set contains various parameters at 5 min resolution. Within the data files is the Xray flux for two wavelength ranges, the magnetic field vectors, the >2 MeV uncorrected elecron fluxes, and the uncorrected alpha-particle fluxes for several energy ranges. | ||||||||||||||||||
| 4) | GOES 6 Space Evironment Monitor Data at 1 min Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/SEM/G/PT1M | ||||||||||||||||||
| ||||||||||||||||||
| This GOES 6 SEM data set contains various parameters at 1 min resolution. Within the data files is the Xray flux for two wavelength ranges, the magnetic field vectors, the >2 MeV uncorrected elecron fluxes, and the uncorrected protons fluxes for several energy ranges. | ||||||||||||||||||
| 5) | GOES 6 Space Evironment Monitor Data at 5 min Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/SEM/G/PT5M | ||||||||||||||||||
| ||||||||||||||||||
| This GOES 6 SEM data set contains various parameters at 5 min resolution. Within the data files is the Xray flux for two wavelength ranges, the magnetic field vectors, the >2 MeV uncorrected elecron fluxes, and the uncorrected protons fluxes for several energy ranges. | ||||||||||||||||||
| 6) | GOES 6 Space Evironment Monitor Data at 5 min Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/SEM/H/PT5M | ||||||||||||||||||
| ||||||||||||||||||
| This GOES 6 SEM data set contains various parameters at 5 min resolution. Within the data files is the Xray flux for two wavelength ranges, the magnetic field vectors, the >2 MeV uncorrected elecron fluxes, and the uncorrected proton and alpha number fluxes for several energy ranges. | ||||||||||||||||||
| 7) | GOES 6 Space Evironment Monitor Data at 5 min Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/SEM/I/PT5M | ||||||||||||||||||
| ||||||||||||||||||
| This GOES 6 SEM data set contains various parameters at 5 min resolution. Within the data files is the Xray flux for two wavelength ranges, the magnetic field vectors, the >2 MeV corrected elecron fluxes, and the uncorrected protons fluxes for several energy ranges. | ||||||||||||||||||
| 8) | GOES 6 Space Evironment Monitor Data at 5 min Resolution |
|
| |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resource ID:spase://VMO/NumericalData/GOES/6/SEM/Z/PT5M | ||||||||||||||||||
| ||||||||||||||||||
| This GOES 6 SEM data set contains various parameters at 5 min resolution. Within the data files is the Xray flux for two wavelength ranges, the magnetic field vectors, the >2 MeV uncorrected elecron fluxes, and the corrected protons fluxes for several energy ranges. | ||||||||||||||||||
| Showing 1 - 8 |